In the economics of solar energy, every additional kilowatt-hour matters. That is precisely why bifacial solar cells — capable of generating electricity from both their front and rear surfaces — have rapidly become the technology of choice for utility-scale and commercial solar projects globally, and increasingly in India.
Websol Energy System Ltd. has been at the forefront of bifacial solar cell manufacturing in India, producing M10 Bifacial Mono PERC solar cells at its Falta SEZ facility in West Bengal. This guide explores the technology, advantages, real-world performance data, and installation considerations for bifacial solar cells — and explains why more project developers are specifying bifacial technology for their next solar installation.
A bifacial solar cell is a photovoltaic cell designed to capture sunlight from both the front (illuminated) side and the rear side. Traditional monofacial cells only generate electricity from photons striking the front surface — any reflected or diffuse light reaching the rear is wasted. Bifacial cells eliminate that waste.
The rear of a bifacial cell is designed to be semi-transparent or passivated rather than opaque, allowing light to reach the active silicon layer from below. This rear-side illumination — primarily from albedo (ground-reflected light), diffuse sky radiation, and inter-row reflected light — generates additional current above and beyond what the front surface alone produces.
The additional energy generated by the rear side, expressed as a percentage of front-side generation, is called the bifacial gain — typically ranging from 5% to 30% depending on:
Websol’s bifacial cells are built on the Mono PERC (Passivated Emitter and Rear Cell) architecture — the same technology that has driven monocrystalline solar efficiency above 23%. What makes Websol’s cells bifacial is the engineering of the rear surface:
This design enables the rear surface to function as a genuine photoactive area — capturing reflected photons and converting them to electricity — while maintaining all the efficiency advantages of the PERC front-side architecture.
📌 Explore Websol’s M10 Bifacial Mono PERC Cell specifications: websolenergy.com/solar-cell
Bifacial gain is the incremental energy yield from the rear side as a percentage of front-side generation. In practice:
Installation Type | Typical Ground Albedo | Estimated Bifacial Gain |
Desert/sandy ground | 25–35% | 15–25% |
Concrete/light paving | 30–40% | 18–28% |
Grass/vegetation | 15–25% | 8–18% |
Dark soil | 8–15% | 5–10% |
White gravel | 50–70% | 25–35% |
Floating solar (water) | 6–10% | 4–8% |
For a 100 MW solar farm in Rajasthan on sandy terrain, a 15% bifacial gain translates to the equivalent of an additional 15 MW of generation capacity — without any additional land, additional modules, or additional inverters. The economics are transformative.
Indian solar auctions in 2024–25 saw discovered tariffs fall below ₹2 per kWh — a milestone driven in significant part by the adoption of high-efficiency bifacial modules that maximise energy yield per rupee of capital investment.
Bifacial cells require bifacial modules — module construction that allows light to reach the rear of the cells. Websol’s bifacial modules use glass-glass construction:
The glass-glass construction delivers multiple benefits beyond bifacial capability:
Getting the maximum value from bifacial solar cells requires installation practices that optimise rear-side light capture:
Increasing the gap between the module rear and the ground from 30 cm to 100 cm can improve bifacial gain by 3–8 percentage points by allowing more ground area to contribute reflected light.
For fixed-tilt installations, using white gravel, reflective membranes, or light-coloured concrete under and around the module row spacing can boost ground albedo from ~20% to 50%+, significantly increasing bifacial gain.
Horizontal single-axis trackers (HSATs) are highly synergistic with bifacial modules. By tilting modules to follow the sun, trackers increase front-side generation; simultaneously, the changing orientation exposes the rear to reflected ground light from different angles throughout the day, improving average bifacial gain.
Increased inter-row pitch reduces shading of the rear side, allowing more sky and ground-reflected diffuse light to reach rear cells. Energy yield simulation (with tools like PVsyst) should be used to optimise the pitch-to-bifacial-gain trade-off.
Some bifacial module designs use frameless or narrow-frame construction to reduce rear-side self-shading — marginally improving bifacial gain in low-mounting-height conditions.
Websol’s M10 Bifacial Mono PERC cells and modules have been deployed across India’s diverse solar landscape:
Utility-Scale Ground Mount (Rajasthan) India’s solar heartland — 300+ days of sun per year, desert soil albedo of 25–35% — is ideal bifacial territory. Websol’s modules have contributed to projects in this region, where bifacial gains consistently exceed 15%.
Commercial Rooftop (Industrial Zones) Light-coloured concrete or metal roofing common in industrial parks provides albedo of 30–40% — enabling meaningful bifacial gains even in rooftop contexts, typically 8–15%.
PM-KUSUM Agricultural Solar Pumps Websol supplied 250 MW of Mono PERC DCR modules (including bifacial variants) to CRI Pumps for PM-KUSUM solar pump projects. Agricultural field albedo varies seasonally — greener crops produce higher albedo — making bifacial modules particularly well-suited for agri-solar applications.
📌 Related: DCR Cell and Module Compliance for Government Schemes →
Factor | Monofacial Mono PERC | Bifacial Mono PERC |
Module cost | Lower | Marginally higher |
Energy yield | Baseline | 5–30% higher |
LCOE | Baseline | 8–20% lower at scale |
Installation complexity | Standard | Slightly higher (mounting height, ground prep) |
Best for | Space-constrained rooftops with low albedo | Ground mount, agri-solar, HSAT tracking |
Lifespan | 25 years | 30+ years (glass-glass) |
For most utility-scale and commercial ground-mount projects in India, bifacial technology offers a clear LCOE advantage. For constrained rooftop situations where mounting height and ground preparation cannot be optimised, the incremental benefit of bifacial is smaller but still positive.
Websol has built bifacial capability into its manufacturing core — not as an add-on but as the standard architecture for M10 Mono PERC cells. The company’s expansion roadmap further deepens this commitment:
4 GW expansion (Phases III & IV by 2028) — next-generation bifacial TOPCon at scale
Bifacial solar cells represent one of the most impactful advances in photovoltaic technology in the last decade — harvesting energy from light that conventional solar panels simply ignored. As India’s solar market matures and developers seek every possible LCOE advantage, bifacial technology has moved from premium option to mainstream standard.
Websol Energy System Ltd. has positioned itself as India’s leading bifacial solar cell manufacturer — combining advanced Mono PERC architecture, glass-glass module construction, and a 1.2 GW automated manufacturing platform to deliver bifacial solar products that meet international quality standards with full domestic compliance credentials.
Bifacial solar cells generate 5–30% more electricity than equivalent monofacial cells, depending on installation conditions, ground albedo, and mounting configuration.
Yes, bifacial modules generate additional power from light reflected off the rooftop surface and diffuse sky light on the rear side. The gain is typically 5–15% for rooftop installations, less than ground-mount configurations.
Websol’s M10 Bifacial Mono PERC cells have a bifacial factor of approximately 75–80%, meaning the rear side generates 75–80% of the front-side output when equally illuminated.
Bifacial modules carry a small premium (typically 2–5%) over monofacial modules of equivalent front-side power. However, the additional energy yield delivers significantly lower LCOE over the system lifetime.
Websol’s bifacial modules use a glass-glass construction with 3.2 mm front tempered glass and 2.0–2.5 mm rear tempered glass, providing superior moisture resistance and longer operational life.
Yes. Websol manufactures its bifacial cells and modules domestically at Falta, West Bengal, making them fully DCR-compliant for eligible government solar projects.
Tools like PVsyst, SAM (NREL), and Heliios can model bifacial gain based on site-specific albedo, mounting configuration, and module parameters. Websol’s technical team can support energy yield analysis for projects using Websol bifacial modules.
We at Websol Energy System Limited respect the privacy of everyone who visits this website and are committed to maintain the privacy and security of the personal information of all visitors to this website.
Our policy on the collection and use of personal information and other information is outlined below.
In case of visiting this website to read or download information, it must be known that Websol Energy System Limited collects and stores a standard set of internet-related information, such as an Internet Protocol (IP) address, the date and time, the type of browser and operating system used, the pages(s) visited. All information is collected to help Websol Energy System Limited for making this site more useful to its customer(s) and only used for statistical purposes.
Websol Energy System Limited collects and uses information such as name, telephone number, email address, etc. in order to:
Except as set out in this privacy policy, Websol Energy System Limited will not disclose any personally identifiable information without permission, unless Websol Energy System Limited is legally entitled or required to do so or if Websol Energy System Limited believes that it is necessary to protect and/or defend it’s rights, property or personal safety etc.
Websol Energy System Limited reserves the full rights to change/alter/amend/modify the contents of the privacy policy from time to time without any prior notice or intimation.
VISITORS TO THIS WEB SITE ARE BOUND BY THE FOLLOWING TERMS AND CONDITIONS (“TERMS”). SO, PLEASE READ THE TERMS CAREFULLY BEFORE CONTINUING TO USE THIS SITE. IF YOU DO NOT AGREE WITH ANY OF THESE TERMS, PLEASE DO NOT USE THIS SITE.
Websol Energy System Limited retains copyright on all the text, contents, graphics and trademarks displayed on this site. All the text, graphics and trademarks displayed on this site are owned by Websol Energy System Limited.
The information on this site has been included in good faith and is for general purpose only and should not be relied upon for any specific purpose. The user shall not distribute text or graphics to others without the express written consent of Websol Energy System Limited. The user shall also not, without Websol Energy System Limited’s prior permission, copy and distribute this information on any other server, or modify or reuse text or graphics on this or any another system.
Although Websol Energy System Limited tries to ensure that all information and recommendations, whether in relation to the products, services, offerings or otherwise (hereinafter “information”), provided as part of this website is correct at the time of inclusion on the web site, Websol Energy System Limited does not guarantee the accuracy of the Information. Websol Energy System Limited makes no representations or warranties as to the completeness or accuracy of Information. Certain links in this site connect to other Web Sites maintained by third parties over whom Websol Energy System Limited has no control. Websol Energy System Limited makes no representations as to the accuracy or any other aspect of information contained in such other Web Sites.
Certain links in this site connect to other websites maintained by third parties over whom Websol Energy System Limited has no control. Websol Energy System Limited makes no representations as to the accuracy or any other aspect of information contained in such other websites.
Websol Energy System Limited hereby disclaims all warranties and conditions with regard to this information, including all implied warranties and conditions of merchantability, fitness for any particular purpose, title and non-infringement.
In no event will Websol Energy System Limited, agents or employees thereof be liable for any decision made by the user and/or site visitor for any inference or action taken in reliance on the information provided in this site or for any consequential, special or similar damages.
Applicable Law and Jurisdiction of this Disclaimer are governed by and to be interpreted in accordance with laws of India, without regard to the choice or conflicts of law provisions of any jurisdiction. The user/site visitor agrees that in the event of any dispute arising in relation to this Disclaimer or any dispute arising in relation to the website whether in contract or tort or otherwise, to submit to the jurisdiction of the courts located at Kolkata (West Bengal) (India) only for the resolution of all such disputes.
Except for the historical information herein, statements in this website, which include words or phrases such as “will”, “aim”, “will likely result”, “would”, “believe”, “may”, “expect”, “will continue”, “anticipate”, “estimate”, “intend”, “plan”, “contemplate”, “seek to“, “future”, “objective”, “goal”, “likely”, “project”, “should”, “potential”, “will pursue”, and similar expressions or variations of such expressions may constitute “forward-looking statements”. These forward-looking statements involve a number of risks, uncertainties and other factors that could cause actual results to differ materially from those suggested by the forward-looking statements. These risks and uncertainties include, but are not limited to our liability to successfully implement our strategy, our growth and expansion plans, obtain regulatory approvals, our provisioning policies, technological changes, investment and business income, cash flow projections, our exposure to the market risks as well as other risks. The company does not undertake any obligation to update forward-looking statements to reflect events or circumstances after the date thereof.